Produkt został dodany do koszyka.

Insulating mats testing

Brak obrazu!

Insulating mast tests according norms EN 61111, ASTM D1048, F479, F1236

Insulation mats class 0, 1, 2, 3, 4

Dimmension 1000x1000mm; 900x900mm; 750x750mm; Testing of other sizes on request

Time / period of testing 12 monthe

Insulating mats testing.

Upon receipt in the laboratory, the mats are documented, washed and dried.

These are then visually checked by our technicians.

The next step is electrical tests at the appropriate voltage for their class using Venko test equipment; finally they are visually inspected again, then stamped and packaged for return to the customer.

Documentation accompanies the mats at all stages of testing, and any damaged mats are recorded and then destroyed.

At the customer’s request, damaged mats can be replaced with new products from our stock.

Thanks to the database we keep, we will remind you about the next testing in any way you like – telephone, e-mail or text message.

 

Price

Service Testing aspects Price
Insulating mats testing 1000x1000mm; 900x900mm; 750x750mm class - 0, 1, 2 5,50 Euro
Insulating mats testing 1000x1000mm; 900x900mm; 750x750mm class - 3, 4 7,50Euro
Non standart Insulating mats testing, widths up to 1220mm class - 0, 1, 2 5,50 Euro per linear meter
Non standart Insulating mats testing, widths up to 1220mm class - 3, 4 7,50 Euro per linear meter